Vue de la page 161
B. Media Type
Minimum Waiting Time: NuApps-MultiUnits-RM will halt at least for the Minimum Waiting Time
you input here during auto-negotiation process.
Media Type Waiting Timeout: If the time spent for auto-negotiation exceeds the Media Type
Waiting Timeout you set here, the test will stop and the test result will be fail.
Media Type: By clicking the scroll-down menu, you can set the transmitting mode to Auto (with
auto-negotiation), Force (without auto-negotiation), or Off (all the ports in this task are link-down).
Media Select: Click the scroll-down menu to choose if all the connecting cables are Copper or
Fiber.
Media Type Fails To Continue: enables the continuation of task running even after reaching the
media type waiting timeout.
C. Packet
Frame Length Setting: As shown in the figure down below, in a standard Ethernet II frame, the
Frame Length (Without CRC) can be from 60~16300 bytes.
By clicking the Frame Length scroll-down menu, you can set the frame length to random (frame
length will be randomly assigned from 60~16300 bytes) or fixed (frame length will be a fixed
number). If you choose fixed as your Frame Length, you can set the frame length in the field